{"product_id":"obvius-leviton-a7810-energy-monitoring-hub-lite","title":"Obvius \/ Leviton A7810 - Energy Monitoring Hub Lite","description":"\u003cdiv\u003e\u003cspan\u003eLeviton Obvius AcquiLite – EMB A7810\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003eObvius’ AcquiLite – EMB A7810 is an intelligent, flexible data acquisition server providing system integrators with the ability to collect energy data from passive pulse output meters. The AcquiLite – EMB A7810 is designed to connect to IP-based software dashboards and kiosks, enterprise energy management applications, as well as demand response and smart grid programs. The AcquiLite – EMB A7810 server lets you benchmark energy usage and reduce energy costs. \u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eAcquiLite Embedded Data Acquisition Server (4 dry pulse inputs, Ethernet), Din \u003cspan\u003eRail Mountable, CE, UL Listing.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eEmbedded (OEM) Solution\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe compact AcquiLite – EMB A7810 footprint and industrial temperature range (-30 to 70C) makes this a perfect solution for embedded applications. Reduce development time and speed up integration by collecting and distributing energy information directly from your equipment.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eData Collection\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe AcquiLite – EMB collects and logs data from connected pulse output or Modbus TCP devices based on user selected intervals. Data from downstream devices are time stamped and stored in non-volatile memory. This interval data is stored locally until the next scheduled upload or manual download. Using an Ethernet (LAN) connection you can push or pull data via HTTP, XML, FTP or any custom protocol utilizing our AcquiSuite Module to build your own application, including integrated cellular communication options.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eInstallation \u0026amp; Features\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003eNo software is required – easily access information through any web browser. There are several additional features including alarming, SNMP Traps, network configuration, USB, security provisions and backlit LCD. Optional cellular communication options are available for wireless internet connectivity.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe AcquiLite – EMB A7810 is compatible with nearly any front-end software platform providing users with a variety of reporting tools; whether it’s a local server or an enterprise wide reporting suite. \u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe EMB A7810 is also an accepted data integration logger to be used with the Panoramic Power Front End. Its data logging, storage and data upload capabilities provides a simple path to integrate I\/O data. The data is stored locally on the EMB A7810 and is uploaded to the Panoramic Power server for dashboarding. Data uploads can range from 1 minute to every 24 hours.  \u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003ePush or pull meter data to energy dashboards, kiosks and software applications\u003c\/li\u003e\n\u003cli\u003eCreate load profiles for energy purchases\u003c\/li\u003e\n\u003cli\u003eUtility submetering (electricity, gas, water, etc.)\u003c\/li\u003e\n\u003cli\u003eMeasurement and verification (M\u0026amp;V)\u003c\/li\u003e\n\u003cli\u003eAccess energy information from local or remote sites\u003c\/li\u003e\n\u003cli\u003eBenchmark building energy usage\u003c\/li\u003e\n\u003cli\u003eView “real time” performance data\u003c\/li\u003e\n\u003cli\u003eTrack energy use and peak demand for Demand Response programs\u003c\/li\u003e\n\u003cli\u003eMonitor utility meters for rebate program compliance\u003c\/li\u003e\n\u003cli\u003eAlarm notification for data points above or below target levels (including SNMP Traps)\u003c\/li\u003e\n\u003cli\u003eLEED \/ Energy Star certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eLeviton A7810-000 Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eARM 9 embedded CPU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating System\u003c\/td\u003e\n\u003ctd\u003eLinux 2.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e32 MB RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash ROM\u003c\/td\u003e\n\u003ctd\u003e16 MB NOR Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterval Recording\u003c\/td\u003e\n\u003ctd\u003e1 to 60 minutes, user selectable (default 15 minutes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLEDs\u003c\/td\u003e\n\u003ctd\u003eEthernet, Pulse (x4), power, alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole\u003c\/td\u003e\n\u003ctd\u003e2 x 16 LCD character, two push buttons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24VDC, 500mA, Required (not included) *This unit is to be sourced by a Class 2 power supply with the following output: 24VDC, 500mA min not to exceed 8A. Note: Only 350mA is required if the USB port is not used.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eRJ45 Ethernet is isolated to 1500VDC from the main board. (Power input, Pulse inputs and USB nonisolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eModbus\/TCP, TCP\/IP, PPP, HTTP\/HTML, FTP, NTP, XML, SNMP-Trap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLAN\u003c\/td\u003e\n\u003ctd\u003eRJ45 10\/100 Ethernet, full\/half duplex, auto polarity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003ctd\u003eUSB expansion port (cellular modem options available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O\u003c\/td\u003e\n\u003ctd\u003e4x Pulse inputs, dry contact, standard or KYZ, closure threshold 100 to 2.5K user selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Rate\u003c\/td\u003e\n\u003ctd\u003ePulse input maximum rate 10Hz, minimum pulse width 50ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003ePulse count values stored in non-volatile memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhysical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.42lbs (0.19g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e4 x 4.25 x 2\" (102 x 108 x 51mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnvironment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNorth America\u003c\/td\u003e\n\u003ctd\u003e-30 to 70°C, 0 to 95% RH, Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e2000M max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution\u003c\/td\u003e\n\u003ctd\u003eDegree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCodes and Standards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissions\u003c\/td\u003e\n\u003ctd\u003eFCC CFR 47 Part 15, Class A, EN 61000, EN61326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eUL61010 Recognized, EN 61010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eLink to Data Sheets and Specifications \u003ca href=\"https:\/\/leviton.com\/products\/a8810\" title=\"https:\/\/leviton.com\/products\/a8810\" target=\"_blank\"\u003ehttps:\/\/leviton.com\/products\/a8810\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eSubmit a question about this product or request for custom configuration: \u003ca href=\"https:\/\/www.emergentmetering.com\/product-support-intake\"\u003ehttps:\/\/www.emergentmetering.com\/product-support-intake\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e","brand":"Leviton \/ Obvius","offers":[{"title":"Default Title","offer_id":43530992255046,"sku":null,"price":800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0666\/8641\/9014\/files\/a7810-3.jpg?v=1752147164","url":"https:\/\/shop.emergentmetering.com\/products\/obvius-leviton-a7810-energy-monitoring-hub-lite","provider":"Emergent Metering","version":"1.0","type":"link"}